Airsys has introduced Arc90, a thermal management architecture for data centres designed around a Power Compute Effectiveness target of up to 0.90.

Arc90 is intended to design, validate and price cooling infrastructure as a single architecture rather than as separate equipment purchases. It combines air, liquid and hybrid cooling approaches and aims to direct up to 90% of a facility's provisioned electrical capacity to IT compute, depending on site conditions, facility boundaries, redundancy requirements and customer specifications.

The launch marks a shift in Airsys' approach to project design and delivery as data centre operators face tighter power constraints. Grid connections can take years to secure, and operators are under pressure to reserve more of the electricity they can obtain for computing workloads rather than cooling and related overheads.

Power Compute Effectiveness, or PCE, is Airsys' metric for measuring how much provisioned electrical capacity within a defined facility boundary is allocated to compute rather than support systems. Unlike Power Usage Effectiveness, which measures operational energy efficiency, PCE is intended to assess allocation decisions at the design stage, before a facility is built or retrofitted.

In practical terms, a PCE of 0.90 means 90MW of every 100MW of provisioned capacity would be assigned to IT compute, with the remaining 10MW going to cooling, electrical losses and other support loads. Airsys said some legacy designs can be closer to 0.70, leaving about 30% of provisioned power assigned to infrastructure overhead before servers are installed.

Yunshui Chen, Founder and Chief Executive Officer of Airsys, set out the company's rationale for the new framework.

"The race to build AI infrastructure is now a race for power. The choices made before construction begins decide how much of that power is ever set aside for compute. Arc90 is how we intend to answer that question with our customers from the first drawing: one architecture, designed and priced around the outcome rather than a list of equipment," said Chen.

How it works

Arc90 replaces a conventional single-loop cooling design with three separate thermal loops matched to different loads. A high-temperature liquid loop is intended for CPUs and GPUs and uses dry coolers and coolant distribution units. A medium-temperature loop handles residual air-side heat with free-cooling chillers. A low-temperature zone uses precision direct expansion cooling for electrical rooms, UPS areas and support spaces.

This separation means chillers are sized only for residual air-side heat rather than the full IT load. In its design modelling, Airsys said that can cut required chiller capacity by as much as 80% compared with a chillers-only design.

The architecture is also designed to a zero evaporative water use effectiveness target. That reflects a broader industry effort to reduce water consumption amid rising scrutiny of the environmental footprint of large data centres.

Airsys provided one modelled example for a hypothetical 60MW facility in the south-eastern United States. Under the same facility boundary and redundancy assumptions, a chillers-only design reached a PCE of 0.74, while an Arc90 configuration targeted 0.90, representing about 22% more provisioned power for compute within the same total facility power. Outcomes, it said, depend on assumptions covering climate, IT load, cooling architecture and electrical losses.

Product lines

The framework is intended to sit across Airsys' five product lines. These include PowerOne for data centre thermal management and dense infrastructure, LiquidPack for retrofit liquid cooling in existing facilities, EdgeOne for modular thermal systems at edge and telecom sites, Aegis for chip-level and component-level cooling, and ComfortOne for commercial and education settings.

For operators with existing air-cooled halls, Airsys plans to apply Arc90 principles through LiquidPack, the new name for its direct-to-server liquid spray cooling platform. The platform is designed to convert servers inside existing air-cooled facilities to single-phase liquid cooling and increase rack density within the same footprint. Airsys is working with server manufacturers, hyperscalers and colocation operators on instrumented trials benchmarked on PCE before and after retrofit.

At the processor level, Aegis is developing a two-phase direct-to-chip cooling system based on a 3D-printed cold plate. Airsys said additive manufacturing allows internal structures that conventional machining cannot produce, with the design intended to increase boiling surface area, move vapour away from the chip and target processor hotspots.

Industry observers said the design-stage focus reflects the economics of current data centre expansion.

"In a power-constrained data center industry, every watt freed from physical infrastructure for AI computing is a win. PCE brings that priority into the design process, focusing on how much of a facility's provisioned power is available to IT rather than supporting infrastructure. Liquid cooling can help reduce cooling power demand, but capturing its full potential requires creative, whole-system thinking. Airsys is taking the right approach by treating cooling as a holistic challenge, addressing both new builds and retrofits of existing facilities," said Galabov.

Moises Levy, PhD, Chief Executive Officer and Founder of DCMETRIX, also commented on the model.

"With limited power availability and data center projects being so capital-intensive, the physical infrastructure goal is clear: deliver as much power as possible to compute in a reliable, efficient and sustainable way. Arc90 brings that vision to the design or retrofit phase, helping organizations get more value from every watt," said Levy.