Sustainability at the rack: Rethinking how data centers turn power into compute

Sustainability at the rack: Rethinking how data centers turn power into compute

Wed, 25th Nov 2026 (Today)
Dr Reza Azizian
DR REZA AZIZIAN CEO Ferveret

Sustainability discussions in AI often begin with where the electricity comes from. That is the right starting point, but focusing exclusively on energy supply can obscure an equally important question: how efficiently is the data centre converting that electricity into useful computing output? Cooling sits at the centre of that question.

Sustainability should be measured in useful work

Power Usage Effectiveness, or PUE, remains an important facility metric. It shows how much of a data center's total energy reaches IT equipment versus supporting infrastructure such as cooling, lighting and power distribution. However, PUE alone does not reveal how efficiently the IT equipment performs once that energy reaches the rack. Two facilities could report similar PUE values while producing very different amounts of useful computing output.

The more complete question is how much useful work a facility produces for every unit of energy and water it consumes. For AI workloads, this is increasingly expressed as performance per watt, or more specifically tokens per watt. NVIDIA CEO Jensen Huang has publicly described this as the right unit of measurement for modern AI infrastructure. The shift reframes cooling's role: it is no longer only an overhead cost to minimise but a lever that affects both the facility overhead and the sustained performance of the computing hardware itself.

Water use must be evaluated locally

Water is another critical variable in the cooling discussion, but its impact cannot be reduced to a single consumption figure. The Environmental and Energy Study Institute reports that large data centres can use up to 5 million gallons of water per day, comparable to the daily consumption of a town of 10,000 to 50,000 people. The environmental significance of that volume depends heavily on local climate and the safe withdrawal capacity of the watershed or groundwater basin. Evaporative cooling may deliver strong energy efficiency in water-abundant regions, while dry or waterless technologies may be more appropriate in arid or water-stressed locations.

Waterless cooling should not be presented as the only responsible approach for every facility. Operators have to weigh energy use, water availability, climate conditions, reliability and total cost together. That said, technologies that reduce or eliminate operational water consumption can meaningfully expand the range of viable sites. They can also reduce exposure to drought restrictions, changing water regulations and competition for municipal supply, pressures that have already produced moratoriums in parts of Virginia, Oregon and other U.S. regions.

Cooling's impact on computing performance

Cooling has traditionally been viewed as a system that keeps equipment from overheating. In modern AI infrastructure, that definition is only partly true. GPUs and other accelerators adjust their operating behaviour based on temperature and power conditions. When thermal limits are reached, processors reduce their clock speeds, a behaviour commonly known as thermal throttling. A cooling system that maintains stable operating temperatures therefore affects not only facility overhead but also the sustained performance of the computing equipment itself.

This is one reason the industry is looking beyond conventional air and basic cold-plate approaches toward denser liquid-based methods. One emerging class of technology, Adaptive Phase Cooling, applies principles associated with subcooled boiling, a heat-transfer process also studied in nuclear engineering. Rather than relying solely on fans or conventional cold plates, these systems use a dielectric fluid and controlled phase change to remove heat from computing components. Small bubbles form at heated surfaces, detach and condense rapidly, transporting heat away from the hardware.

In testing conducted through a collaboration with UCLA's Intelligent Connectivity Labouratory using NVIDIA H200 GPUs, an Adaptive Phase Cooling system demonstrated a 15 per cent improvement in computational efficiency, measured in teraflops per kilowatt, compared with a direct-to-chip liquid-cooling configuration. The system achieved a PUE of approximately 1.03, meaning roughly 97 per cent of facility power was directed toward computing. UCLA researchers also observed that the cooling approach allowed the hardware to maintain higher sustained clock speeds, reducing the time required to train machine-learning models. No single benchmark can represent every production environment, but evaluating cooling by both thermal performance and computational output is a necessary step toward more complete sustainability accounting.

Industry leadership requires transparent measurement

Claims of sustainability should be supported by operating data. Data centre operators and technology providers should be prepared to report how cooling systems perform across changing workloads, seasons and ambient conditions, not only at design point conditions. ASHRAE's TC 9.9 guidance for high-density equipment provides a useful shared vocabulary for reporting coolant supply and return temperatures, inlet envelopes and the operating conditions behind efficiency claims.

Sustainable infrastructure will require operators to optimise the entire path from the electrical connection to the final computational output. Clean electricity remains essential, but generating more useful work from every available watt is equally important. As AI infrastructure expands, the industry leaders will be those who demonstrate that higher computing performance does not have to produce a proportional increase in resource consumption. Cooling technology will be one of the most important tools for achieving that balance, and it should be treated as a core component of sustainable computing strategy rather than an afterthought.